Introduction
The procedures in this document describe the configuration steps required to configure the Infinidat InfiniBox for use with Dell EMC VPLEX, a virtual storage technology that connects to multiple storage arrays, allowing for data migration and mirroring across sites.
Zeroing the volumes metadata
The metadata and logging volumes must be zeroed before they can be used. Use a utility (like dd) to write zeros across the volume.
Example:
dd if=/dev/zero of=/dev/sdbg conv=notrunc
METADATA VOLUMES
Metadata volumes are critical to the proper function of the VPLEX system. VPLEX Meta Data Volumes, or Meta Volumes, contain information about devices, physical-to-virtual device mappings and other internal system configuration data. The importance of the information on these volumes justifies a high level of Meta Volume data redundancy. Meta Volumes are provisioned as RAID 1 along with a minimum of two additional point-in-time copies (one 24 hours old, the other 48 hours old). It is highly recommended that Meta Volumes RAID 1 members be stored on two physically separate storage arrays, using array-provided RAID protection for each member.
LOGGING VOLUMES
A logging volume is dedicated capacity for tracking any blocks written to a cluster. A logging volume is a required prerequisite to creating a distributed device and a remote device. Logging volumes keep track of any blocks written during inter-cluster link failure. The system uses the information in logging volumes to synchronize the distributed devices by sending only changed block regions across the link.
USER DATA VOLUMES
VPLEX virtualizes physical storage array devices and applies three layers of logical abstraction to the storage volumes. VPLEX uses extents to divide storage volumes and applies various RAID geometries (i.e. RAID-0, RAID-1, or RAID-c) to them within in the device layer. Devices are built using one or more extents and can be combined into more complex RAID schemes and device structures as desired (i.e. storage volumes encapsulation which consist in importing back-end array into an instance of VPLEX and used while keeping their data intact).
VIRTUAL VOLUMES
At the top layer of the VPLEX storage structures are virtual volumes. Virtual volumes are the elements VPLEX exposes to hosts using its front-end (FE) ports. Access to virtual volumes is controlled using storage views. They act as logical containers determining host initiator access to VPLEX FE ports and virtual volumes.
Provisioning InfiniBox storage for VPLEX
Provisioning of InfiniBox storage to work with VPLEX takes the following steps.
Fabric and Zoning configuration
Connect the VPLEX engines to the SAN fabric, and zone the InfiniBox storage array target ports to the VPLEX back-end ports. Follow the recommendations in the "Implementation and Planning Best Practices for Dell EMC VPLEX Technical Notes".
The general rule is to use a configuration that provides the best combination of simplicity and redundancy. For back-end Storage connectivity the recommended SAN topology is a dual SAN fabric design to supply redundant and resilient inter-hardware connectivity.
- Each director in a VPLEX cluster must have a minimum of two paths to every backend storage array.
- InfiniBox contains three or more independent interconnected nodes. Each node should have a minimum of two ports connected to the VPLEX back-end ports via physically separate SAN fabrics.
- When configuring mirroring or migration across arrays, it is suggested that each array be accessed through different back-end director ports
- A maximum of 4 active paths per director to a given LUN is recommended. This is considered optimal because each director will load balance across the four active paths to the storage volume.
ZONING RECOMMENDATIONS
Physical connectivity
- Each VPLEX Director is connected to two FC Switches (Fabric A and Fabric B)
- Each InfiniBox Node is connected to two FC Switches (Fabric A and Fabric B)
- Even Numbered (0,2) VPLEX Director ports are connected to Fabric A
- Odd Numbered (1,3) VPLEX Director ports are connected to Fabric B
- InfiniBox Fabric A ports use HBA-1 (Ports 1-4)
- InfiniBox Fabric B ports use HBA-2 (Ports 5-8)
Logical zoning
- Zone VPLEX director A-00 ports to Port 1 of InfiniBox Node 1 and Node 2
- Zone VPLEX director B ports to one group of Port 5 on each InfiniBox Nodes.
- Repeat for additional VPLEX engines.
- Create a separate host-initiator for each VPLEX cluster.
- Map Volumes to allow access to the appropriate VPLEX initiators for each port groups.
SAMPLE THREE ENGINE DUAL FABRIC ZONING
Fabric | VPLEX Engine | VPLEX Director | VPLEX Port | InfiniBox Node | InfiniBox Port | Suggested InfiniBox Host Name |
---|---|---|---|---|---|---|
A | Engine 1 | Director A1 | FC00 | Node 1 | N1FC1 | vplex_A1_FC00_FC01 |
B | Engine 1 | Director A1 | FC01 | Node 1 | N1FC5 | |
A | Engine 1 | Director B1 | FC00 | Node 2 | N2FC1 | vplex_B1_FC00_FC01 |
B | Engine 1 | Director B1 | FC01 | Node 3 | N3FC5 | |
A | Engine 2 | Director A2 | FC00 | Node 2 | N2FC1 | vplex_A2_FC00_FC01 |
B | Engine 2 | Director A2 | FC01 | Node 2 | N2FC5 | |
A | Engine 2 | Director B2 | FC00 | Node 3 | N3FC1 | vplex_B2_FC00_FC01 |
B | Engine 2 | Director B2 | FC01 | Node 1 | N1FC5 | |
A | Engine 3 | Director A3 | FC00 | Node 3 | N3FC1 | vplex_A3_FC00_FC01 |
B | Engine 3 | Director A3 | FC01 | Node 3 | N3FC5 | |
A | Engine 3 | Director B3 | FC00 | Node 1 | N1FC1 | vplex_B3_FC00_FC01 |
B | Engine 3 | Director B3 | FC01 | Node 2 | N2FC5 | |
A | Engine 1 | Director A1 | FC02 | Node 3 | N3FC1 | vplex_A1_FC02_FC03 |
B | Engine 1 | Director A1 | FC03 | Node 2 | N2FC5 | |
A | Engine 1 | Director B1 | FC02 | Node 1 | N1FC1 | vplex_B1_FC02_FC03 |
B | Engine 1 | Director B1 | FC03 | Node 1 | N1FC5 | |
A | Engine 2 | Director A2 | FC02 | Node 1 | N1FC1 | vplex_A2_FC02_FC03 |
B | Engine 2 | Director A2 | FC03 | Node 3 | N3FC5 | |
A | Engine 2 | Director B2 | FC02 | Node 2 | N2FC1 | vplex_B1_FC02_FC03 |
B | Engine 2 | Director B2 | FC03 | Node 2 | N2FC5 | |
A | Engine 3 | Director A3 | FC02 | Node 2 | N2FC1 | vplex_A3_FC02_FC03 |
B | Engine 3 | Director A3 | FC03 | Node 1 | N1FC5 | |
A | Engine 3 | Director B3 | FC02 | Node 3 | N3FC1 | vplex_B1_FC02_FC03 |
B | Engine 3 | Director B3 | FC03 | Node 3 | N3FC5 |
The above table represents the perfect distribution possible between VLEX cluster and InfiniBox systems. Each InfiniBox FC port is zoned to exactly 4 distinct VPLEX ports on different directors.
If there are fewer than 3 engines, or fewer ports connected per director, zone them according to the relevant subset of the above table.
AN EXAMPLES OF BROCADE ZONING CONFIGURATION
Fabric A
cfg: VPLEX_NFINIDAT_FABA InfiniBox_PLEXE1_DIRA_FABA; InfiniBox_PLEXE1_DIRB_FABA zone: InfiniBox_PLEXE1_DIRA_FABA infinidat_node01_port01; infinidat_node02_port01; vplex_c1e1_a1_00 zone: InfiniBox_PLEXE1_DIRB_FABA infinidat_node01_port01; infinidat_node03_port01; vplex_c1e1_b1_01 alias: vplex_c1e1_a1_00 50:00:XX:XX:60:XX:f1:10 alias: vplex_c1e1_b1_01 50:00:XX:XX:70:XX:f1:11 alias: infinidat_node01_port01 57:42:XX:XX:XX:XX:28:11 alias: infinidat_node02_port01 57:42:XX:XX:XX:XX:28:21 alias: infinidat_node03_port01 57:42:XX:XX:XX:XX:28:31
Fabric B
cfg: VPLEX_NFINIDAT_FABB InfiniBox_PLEXE1_DIRA_FABB; InfiniBox_PLEXE1_DIRB_FABB zone: InfiniBox_PLEXE1_DIRA_FABB infinidat_node02_port05; infinidat_node03_port05; vplex_c1e1_a1_01 zone: InfiniBox_PLEXE1_DIRB_FABB infinidat_node02_port05; infinidat_node03_port05; vplex_c1e1_b1_00 alias: vplex_c1e1_a1_01 50:00:XX:XX:60:XX:f1:11 alias: vplex_c1e1_b1_00 50:00:XX:XX:70:XX:f1:10 alias: infinidat_node01_port05 57:42:XX:XX:XX:XX:28:15 alias: infinidat_node02_port05 57:42:XX:XX:XX:XX:28:25 alias: infinidat_node03_port05 57:42:XX:XX:XX:XX:28:35
InfiniBox Provisioning
Hosts, and then clusters must be created on InfiniBox in order to map provisioned storage volumes. Hosts are groupings of initiators that are associated to a physical host, and clusters are user defined as a grouping of those hosts.
Creating multiple hosts and cluster allows simple association of InfiniBox volumes to the VPLEX engines:
- Each host entity in InfiniBox should represent two ports of a VLPEX director, each connected to a different fabric.
For example, a host entity may represent the ports FC00 and FC01 of director A1. A different host entity may represent ports FC00 and FC01 of director A2. - Group all the host entities in a single cluster entity, to allow mapping of the InfiniBox volumes to all the VPLEX directors in one go.
Once created, InfiniBox volumes can be mapped to all grouped initiators of a given connected host.
The above table provides a simple way to name the InfiniBox host entities. Using names that help identify the initiators facilitates maintenance and lifecycle activities.
If there are fewer than 3 engines, or fewer ports connected per director, zone them according to the relevant subset of the above table.
CREATING A HOST
Suggestions for friendly host names are ones that describe the host being created.
Step 1 | On the InfiniBox GUI, click the Hosts & Clusters button on the toolbar on the left. |
Step 2 | Click on Create Host. |
CREATING A CLUSTER
Step 1 | On the InfiniBox GUI, click the Hosts & Clusters button on the toolbar on the left. The Hosts & Clusters screen opens. |
Step 2 | Click on Create Cluster. The Create Cluster screen opens. Insert a name for the cluster and click Create. |
Step 3 | Click the cluster and add host(s).
Click them one by one. Click the Add button. The hosts are added to the cluster. |
CREATING A POOL
Step 1 | On the InfiniBox GUI, click the Pools button on the toolbar on the left. The Pools screen opens. |
Step 2 | Click on Create Pool. The Create Pool screen opens. Insert a name for the pool and provision physical capacity. By default, the virtual capacity is coupled with the physical. It is possible to decouple them, of course. |
CREATING A VOLUME
Step 1 | On the InfiniBox GUI, click the Volumes button on the toolbar on the left. The Volumes screen opens. -OR- Right-click the pool and select Create Volume from the menu. The Create Pool screen opens. |
Step 2 | Insert a name for the volume and provision its capacity. Set the pool that the volume belongs to (no need to set this, if you create the volume from the pool's screen). Click Create. The volume is created. In our example, 10 volumes were created and they are available on the Volumes screen: |
MAPPING A VOLUME TO A HOST OR A CLUSTER
Step 1 | Select a host and click Map Volume. |
Step 2 | Select volumes from the list and click Map. The volumes are mapped to the host. Auto LUN Assignment is enabled by default. OPTIONALLY: Check the "Assign LUN Manually" box to allow for manual LUN assignment if required. |
VPLEX Provisioning
In order to present devices to hosts, there are a number of steps to follow when provisioning storage on the VPLEX:
- LUNs created on the InfinBox are mapped to the VPLEX ports. Appropriate zoning must be configured on the fibre channel switch that is attached to both devices.
- VPLEX is configured to claim the mapped LUNs. Extents are created on the claimed LUNs.
- Stripes, mirrors or concatenated (RAID 0,1, and C geometries respectively) devices can be provisioned by combining the created extents depending on application performance/resilience and capacity requirements. Additionally encapsulated (1:1 mapped) devices can be created when claimed LUN data is required to be preserved and 'imported' into the VPLEX
- The aforementioned device raid geometries can be spanned across VPLEX clusters to provide geographically diverse VPLEX raid configurations
- Distributed devices consist of same sized devices created on VPLEX clusters. Consistency groups ensure consistency across distributed devices.
- Virtual device are created from these device types and are then exported to connected hosts.
Creating a name mapping file for VPLEX for third-party arrays
Create a mapping file to batch claim multiple LUNs exported from the InfiniBox array:
Step 1 | Login to the vplexcli. |
Step 2 | Change context to the storage volumes on the VPLEX cluster being exported to. For example: VPlexcli:/>cd /clusters/cluster-1/storage-elements/storage-volumes> |
Step 3 | List all storage volumes: VPlexcli:/clusters/cluster-1/storage-elements/storage-volumes> ll Name VPD83 ID Capacity Use Vendor IO Type Thin VIAS ---------------------------------------- ---------------------------------------- -------- --------- -------- Status ----------- Rebuild Based ---------------------------------------- ---------------------------------------- -------- --------- -------- ------ ----------- ------- ----- VPD83T3:6742b0f0000004280000000000005cae VPD83T3:6742b0f0000004280000000000005cae 2G unclaimed NFINIDAT alive traditional false false VPD83T3:6742b0f0000004280000000000005caf VPD83T3:6742b0f0000004280000000000005caf 2G unclaimed NFINIDAT alive traditional false false VPD83T3:6742b0f0000004280000000000005cb0 VPD83T3:6742b0f0000004280000000000005cb0 2G unclaimed NFINIDAT alive traditional false false VPD83T3:6742b0f0000004280000000000005cb1 VPD83T3:6742b0f0000004280000000000005cb1 2G unclaimed NFINIDAT alive traditional false false |
Step 4 | Cut and paste the command output and save it to a file in the /tmp folder of the management server. |
Step 5 | Each claimed lun needs a unique name – preselect a unique string that will help identify LUNs to be claimed. Names:
Examples: INFINIDAT_20140101 INFINDAT_aa3721_ |
---|---|
Step 6 | Type the following command on the management server: cat /tmp/file1 |awk '{print $2, "claim_name"NR" "}' > /var/log/ VPlex/cli/filename{_}.txt Where:
Example: service@VPLEX01:/tmp> cat /tmp/file1 | awk '{print$2, "volume_"NR" "}' > /tmp/NFINIDAT.txt service@VPLEX01:/tmp> cat /tmp/NFINIDAT.txt VPD83T3:6742b0f0000004280000000000005cae volume_1 VPD83T3:6742b0f0000004280000000000005caf volume_2 VPD83T3:6742b0f0000004280000000000005cb0 volume_3 VPD83T3:6742b0f0000004280000000000005cb1 volume_4 service@VPLEX01:/tmp> Edit filename.txt to add the phrase Generic storage-volumes to the very top of the file. TIP: The Linux based VPLEX management console includes vim which can be used to create and edit files text files. |
Step 7 | Enter the following command to claim the LUNs using the VPLEX claimingwizard. Example: service@VPLEX01:/tmp> vplexcli Trying ::1... Connected to localhost. Escape character is '^]'. Enter User Name: service Password: creating logfile:/var/log/VPlex/cli/session.log_service_localhost_T10175_20150205190610 VPlexcli:/clusters/cluster-1/storage-elements/storage-volumes> claimingwizard -f /tmp/NFINIDAT.txt -c cluster-1 Found unclaimed storage-volume VPD83T3:6742b0f0000004280000000000005cb1 vendor NFINIDAT : claiming and naming NFINIDAT_volume_4. Found unclaimed storage-volume VPD83T3:6742b0f0000004280000000000005caf vendor NFINIDAT : claiming and naming NFINIDAT_volume_2. Found unclaimed storage-volume VPD83T3:6742b0f0000004280000000000005cb0 vendor NFINIDAT : claiming and naming NFINIDAT_volume_3. Found unclaimed storage-volume VPD83T3:6742b0f0000004280000000000005cae vendor NFINIDAT : claiming and naming NFINIDAT_volume_1. Claimed 4 storage-volumes in storage array NFINIDAT Claimed 4 storage-volumes in total. VPlexcli:/clusters/cluster-1/storage-elements/storage-volumes> VPlexcli:/clusters/cluster-1/storage-elements/storage-volumes> ll Name VPD83 ID Capacity Use Vendor IO Type Thin VIAS ---------------------------------------- ------------------------------- --------- -------- --------- -------- Status ----------- Rebuild Based ---------------------------------------- --------------------------------------- -------- --------- -------- ------ ----------- ------- ---- NFINIDAT_volume_1 VPD83T3:6742b0f0000004280000000000005cae 2G claimed NFINIDAT alive normal false false NFINIDAT_volume_2 VPD83T3:6742b0f0000004280000000000005caf 2G claimed NFINIDAT alive normal false false NFINIDAT_volume_3 VPD83T3:6742b0f0000004280000000000005cb0 2G claimed NFINIDAT alive normal false false NFINIDAT_volume_4 VPD83T3:6742b0f0000004280000000000005cb1 2G claimed NFINIDAT alive normal false false |
Create a meta-volume
As discussed, VPLEX requires four LUNs (min 78GB) for metadata volumes.
Step 1 | Export the LUNs from the array |
Step 2 | Use the configuration show-meta-volume-candidates command to display possible candidates. VPlexcli:/clusters/cluster-1/system-volumes> configuration show-metavolume-candidates Name Capacity Vendor IO Status Type Array Name ---------------------------------------- -------- -------- --------- ----------- ---------------------- VPD83T3:6742b0f00000042800000000000118d2 90G NFINIDAT alive traditional NFINIDAT-InfiniBox-b0f000 VPD83T3:6742b0f00000042800000000000118d3 90G NFINIDAT alive traditional NFINIDAT-InfiniBox-b0f000 VPD83T3:6742b0f00000042800000000000118d4 90G NFINIDAT alive traditional NFINIDAT-InfiniBox-b0f000 VPD83T3:6742b0f00000042800000000000118d5 90G NFINIDAT alive traditional NFINIDAT-InfiniBox-b0f000 |
Step 3 | Use the meta-volume create command to create a new meta-volume. The syntax for the command is: meta-volume create --name meta-volume_name --storage-volumes storagevolume_1,storage-volume_2,storage-volume_3 Where:
The mirror can consist of multiple storage volumes (which will become a RAID 1), in which case you would include each additional volume, separated by commas. The meta-volume and mirror must be on separate arrays, and should be in separate failure domains. This requirement also applies to the mirror volume and its backup volume. Storage volumes must be unclaimed and on different arrays. VPlexcli:/clusters/cluster-1/system-volumes> ll c1_meta /clusters/cluster-1/system-volumes/c1_meta: Attributes: Name Value ---------------------- ------------ active true application-consistent false block-count 23592704 block-size 4K capacity 90G component-count 2 free-slots 64000 geometry raid-1 health-indications [] health-state ok locality local operational-status ok ready true rebuild-allowed true rebuild-eta - rebuild-progress - rebuild-status done rebuild-type full slots 64000 stripe-depth - system-id c1_meta transfer-size 128K vias-based false volume-type meta-volume Contexts: Name Description ---------- ------------------------------------------------------------------- components The list of components that support this device or system virtual volume. VPlexcli:/clusters/cluster-1/system-volumes/c1_meta> ll components/ /clusters/cluster-1/system-volumes/c1_meta/components: Name Slot Type Operational Health Capacity ---------------------------------------- Number -------------- Status State -------- ---------------------------------------- ------ -------------- ----------- ------ -------- VPD83T3:6742b0f00000042800000000000118d2 0 storage-volume ok ok 90G VPD83T3:6742b0f00000042800000000000118d3 1 storage-volume ok ok 90G Use the ll command to display the new meta-volume’s status, verify that the attribute active shows a value of true. |
.Create a logging device
Step 1 | On VPLEX, claim the devices: VPlexcli:/clusters/cluster-1/storage-elements/storage-volumes> claim VPD83T3:6742b0f0000004280000000000303442 -n se-logging-source01 VPlexcli:/clusters/cluster-1/storage-elements/storage-volumes> claim VPD83T3:6742b0f0000004280000000000303443 -n se-logging-source02 |
Step 2 | On VPLEX, create extents: VPlexcli:/clusters/cluster-1/storage-elements/storage-volumes> extent create -d se-logging-source01, se-logging-source02 |
Step 3 | Create the logging volume. The syntax for the command is: logging-volume create --name name --geometry [raid-0 |raid-1] --extents context-path --stripe-depth Where:
extents extent_se-logging-source01_1,extent_se-logging-source02_1 Logging-volume 'c1-logging-volume_vol' is created at /clusters/cluster-1/system-volumes. VPlexcli:/clusters/cluster-1/system-volumes> ll Name Volume Type Operational Health Active Ready Geometry Component Block Block Capacity Slots ------------------------------- -------------- Status State ------ ----- -------- Count Count Size -------- ----- ------------------------------- -------------- ----------- ------ ------ ----- -------- --------- -------- ----- -------- ----- c1-logging-volume_vol logging-volume ok ok - - raid-1 2 262560 4K 1G - VPlexcli:/clusters/cluster-1/system-volumes/c1-logging-volume_vol> ll components/ /clusters/cluster-1/system-volumes/c1-logging-volume_vol/components: Name Slot Type Operational Health Capacity ------------------------- Number ------ Status State -------- ------------------------- -------- ------ -------------- -------- -------- extent_se-logging-source01_1 0 extent ok ok 1G extent_se-logging-source02_1 1 extent ok ok 1G |
Create a user device
Storage presented to the back end is provisioned to hosts through the front end. Advanced provisioning options allow devices to be striped, mirrored, and concatenated as required by the host and application environments.
On a cluster, click on Storage Array, select the array and then "Show Logical Units". These are the devices that the cluster can see; ensure that the cluster can see the LUNs you intend to use to create your devices.
Step 1 | Claim the storage volume. VPlexcli:/clusters/cluster-1/storage-elements/storage-volumes> claim VPD83T3:6742b0f0000004280000000000003434 -n se-oralog-vmax VPlexcli:/clusters/cluster-1/storage-elements/storage-volumes> claim VPD83T3:6742b0f0000004280000000000003435 -n se-oraredo-vmax VPlexcli:/clusters/cluster-1/storage-elements/storage-volumes> claim VPD83T3:6742b0f0000004280000000000003436 -n se-oradata-vmax VPlexcli:/clusters/cluster-1/storage-elements/storage-volumes> |
Step 2 | Create extents. In order to create the extents, click Provision Storage, Cluster-1, physical storage, Storage Volumes, you should see your newly claimed volumes as well as any other devices; they can be used or unclaimed. Provision Storage > Cluster-1 > Physical Storage
The VPLEX will automatically populate the left side with any possible candidates; choose the LUNs you want and add them to the right side. |
Step 3 | Create Devices from extents. From the extents, devices can be created, either using a 1:1 mapping of extent to device, or multiple extents per device. Provision Storage > Cluster-1 >Devices
|
Step 4 | Create Virtual Volumes In order to create a virtual volume click Provision Storage, Cluster-1, Virtualized Storage and Virtual Volumes: Provision Storage > Cluster-1 >Virtual Volumes
|
Step 5 | Create Storage View
|
Dell EMC VPLEX-assisted data relocation
VPLEX migrations are non-disruptive. The applications do not need to be stopped in order to migrate storage. VPLEX is fully heterogeneous. It supports both EMC and non-EMC arrays.
There are two primary use cases for data relocation:
- Tech-refresh of an old array: In this use case, a new array is placed under VPLEX management. Volumes from an existing array are migrated onto the new array. Typically, the older array is then retired or repurposed.
- Load balancing across arrays: In this use case, there are multiple arrays behind VPLEX. Either because of capacity reasons or performance reasons or the need for some specific capability, volumes need to be moved from one array to another. Both arrays continue to be kept in service after the volume moves are complete.
VPLEX Local can be used to accomplish both use cases above.
VPLEX Metro adds one more variant to the above scenarios:
- Migrating across arrays across data centers. VPLEX Metro extends the pool of arrays that you can manage beyond the confines of your data center.
Available operations:
- Extent - performs intra-cluster move of data from one extent to another.
- Device - performs intra-cluster move of data from one device to another.
- Batch - a CLI only option that groups extent or device mobility jobs into a batch job.
Migration procedure
- Create a batch migration plan. A plan is a file that identifies the source and target devices and other attributes.
- Check the plan and then start the migration session.
- Verify the status of the migration.
- Verify that the migration has completed. When the migration completes the percentage done will show 100.
- Once the synchronization completes, the migration session can be committed.
- Clean up the migration. This dismantles the source device down to the storage volume and the source storage device is changed to an unclaimed state.
- Remove all information about the migration session from the VPLEX.
- Post-Migration task, depends if you want to redeployed the devices for other uses in the VPLEX or if the source storage system needs to be removed by performing the necessary masking, zoning, and other configuration changes.
Migration Steps
Initial state | Host writing I/Os to VPLEX virtual volume. |
Step 1 | Add target array and expose volumes to VPLEX. |
Step 2 | Establish mirror between source volume and target volume.
|
Step 3 | VPLEX ensures that the volumes on the two arrays are in sync. Host READ I/Os are directed to the source leg. Host WRITE I/Os are sent to both legs of the mirror. After both volumes are in complete sync, I/Os continues until you decide to disconnect the source volume. Even after the volumes are in sync, you have the option to remove the destination volume and go back to the source. |
Step 4 | Once volumes are in sync, disconnect the source volume / array. |
Migration Example using the Unisphere for VPLEX UI
Step 1 | Identify Volume(s) to be migrated. For each volume, identify the geometry (RAID type), members (devices) and device size. Taking note of volume size (Blocks x Block size). The size of the volumes must be the same or larger size that the source devices to be replaced. |
Step 2 | Select add remote mirror. |
Step 3 | Select the device that you want to mirror and then click next. |
Step 4 | On the next screen select each source and target device. Click both devices and Add Mirror. |
Step 5 | Click next to synchronize data, which will bring you to the consistency group page. At this time you can choose to create a new group, add to an existing group or no group at all. We will create a new Consistency Group at this time. |
Step 6 | Commit your changes. |
Step 7 | If you check Distributed Devices now, you will see your newly created mirrored device. |
Step 8 | You'll notice that you have an "unexported" tag under the service status. This means that the device has not yet been masked to an initiator and therefore now storage views exist for this volume. |
Step 9 | If you go back to Cluster-1 and then click on Storage Views. You'll see that there already exists a view that includes the initiator as well as the ports on the VPLEX that present storage out to hosts. Go to the Virtual Volumes tab and you'll see the volumes that are already presented out to the host. Add your virtual volume. |
Considerations and best practices
- Schedule data migration during off-hours to minimize the impact of an increased workload on the back end
- Consider pausing data migration during critical hours of production and resuming it during off-peak hours.
- Up to 25 migration sessions can run concurrently on a VPLEX system. Additional sessions can be defined and queued for execution. When a running session completes, a queued session will begin.
- Migrate one server or cluster at a time.
- The default transfer size value is 2 MB. It is configurable for 4 KB to 32MB. When the transfer size is set large, migration will be faster but potentially could impact performance on the front end. Smaller transfer size will result in less front-end impact but migrations will take longer.
- A batch can process either extents or devices, but not a mix of both.
- Batch mobility can only be performed via the CLI.
Best practices recommendations when provisioning Virtual Devices
CONSIDERATIONS FOR META-VOLUMES:
- For each VPLEX cluster, allocate four storage volumes of at least 80 GB as metadata volumes.
- Configure the metadata volumes for each cluster with multiple back-end storage volumes provided by different storage arrays of the same type.
- Use Infini-RAID for metadata volumes. The data protection capabilities provided by these storage arrays ensure the integrity of the system's metadata.
- Read caching should be enabled.
- A hot spare meta-volume must be preconfigured in case of a catastrophic failure of the active meta-volume.
CONSIDERATIONS FOR LOGGING DEVICES
VPLEX uses logging devices to track changes during a loss of connectivity or loss of a volume that is a mirror in a distributed device.
- Use Infini-RAID for logging volumes. The data protection capabilities provided by the storage array ensure the integrity of the logging volumes.
- Each VPLEX cluster should have sufficient logging volumes to support its distributed devices. The logging volume must be large enough to contain one bit for every page of distributed storage space. See EMC documentation.
- For logging volumes the best practice is to mirror them across two or more back-end arrays to eliminate the possibility of data loss on these volumes.
You can have more than one logging volume, and can select which logging volume is used for which distributed device.
- Volumes that will be used for logging volumes must be initialized (have zeros written to their entire LBA range) before they can be used.
CONSIDERATIONS FOR USER VOLUMES
- Extents should be sized to match the desired virtual volume's capacity. Do not create smaller extents and then use devices to concatenate or stripe the extents. When disk capacities are smaller than desired volume capacities, best practice is to create a single slice per disk, and use RAID structures to concatenate or stripe these slices into a larger user volume.
- Each storage view contains a list of host/initiator ports, VPLEX FE ports, and virtual volumes. A one-to-one mapping of storage view and host is recommended.
- Each storage view should contain a minimum of two director FE ports, one from an A director and one from a B director.
- A storage view should contain a recommended minimum of two host initiator ports.