Follow

Configuring the Virtual I/O Server to work with InfiniBox

Here is how to configure the Virtual I/O Server to work with InfiniBox:

First connect to the server using the command:

ssh padmin@<server-ip>

Run the following command to get root privilege:

$ oem_setup_env 

Install the Infinidat ODM Package

  1. Download the package located here:
    https://repo.infinidat.com/packages/main-stable/index/packages/infinidat-odm/releases/2.2.3.2/distributions/aix-5.3/architectures/powerpc/extensions/rpm/infinidat-odm-2.2.3.2-aix-5.3-powerpc.rpm
  2. Install the rpm package using the command:

    # rpm -Uvh /home/padmin/infinidat-odm-2.2.3.2-aix-5.3-powerpc.rpm
    infinidat-odm ##################################################
    Cleaning up old infinidat odm definitions...
    Adding infinidat.odm...
    Applying the new attributes for the boot processes with bosboot...
    Installing message catalog...
  3. To verify that the odm has been registered run the following command:

    # odmget PdAt | grep -p NFINIDAT | wc -l
         583

Error Recovery Policy Check

Run:

# lsparent -C -k fcp -F name
fscsi0
fscsi1
fscsi2
fscsi3
fscsi4
fscsi5


Repeat
for each FC Adapter. We can check the fc_err_recov policy with the command:

# lsattr -El fscsi0
attach       switch    How this adapter is CONNECTED         False
dyntrk       yes       Dynamic Tracking of FC Devices        True+
fc_err_recov fast_fail FC Fabric Event Error RECOVERY Policy True+
scsi_id      0x1f5000  Adapter SCSI ID                       False
sw_fc_class  3         FC Class for Fabric                   True 


If the policy is not fast_fail you can change it using the command:

chdev -l fscsi0 -a fc_err_recov=fast_fail


Verification

  1. Check that the error recovery policy is fast_fail.
    First we need to find which HBA's are being used, this is queried by the command:

  2. After mapping devices to the VIOS server you can view disk properties using the following commands:

    # lsdev -Cc disk
    hdisk0  Available 00-00-00 SAS Disk Drive
    hdisk1  Available 00-00-00 SAS Disk Drive
    hdisk2  Available 03-00-02 INFINIDAT Fibre Channel Disk (InfiniBox)
    hdisk3  Available 03-00-02 INFINIDAT Fibre Channel Disk (InfiniBox)
    hdisk4  Available 03-00-02 INFINIDAT Fibre Channel Disk (InfiniBox)
    hdisk5  Available 03-00-02 INFINIDAT Fibre Channel Disk (InfiniBox)
    hdisk6  Available 03-00-02 INFINIDAT Fibre Channel Disk (InfiniBox)

    For a specific disk you can run:

    # lscfg -vl hdisk6
      hdisk6           U78AA.001.WZSHLLA-P1-C5-T1-W5742B0F000047E11-L5000000000000  INFINIDAT Fibre Channel Disk (InfiniBox)
    
            Manufacturer................NFINIDAT
            Machine Type and Model......InfiniBox
            ROS Level and ID............30682020
            Serial Number...............
            Device Specific.(Z0)........0000053245181002
            Device Specific.(Z1)........

    To check the number of paths for each disk, run the command:

    # lspath -l hdisk6
    Enabled hdisk6 fscsi0
    Enabled hdisk6 fscsi0
    Enabled hdisk6 fscsi1
    Enabled hdisk6 fscsi2
    Enabled hdisk6 fscsi2
    Enabled hdisk6 fscsi3
    Enabled hdisk6 fscsi3